Required Residential Inspections

Once you have received the necessary residential permits,  you must schedule inspections at certain points in the construction process. When you schedule your inspection, please have a copy of the approved permit, plat and building plans on the job site and available to the inspector during each inspection. It is the responsibility of the permit holder or the permit holder’s representative to notify the county when the stages of construction are reached that requires an inspection. Ladders, scaffolds and testing equipment required to complete an inspection must be provided.

Call Arlington to schedule your inspection appointment 24 hrs in advance. Please have your permit number available when scheduling an inspection.

  • Integrated Voice Response (IVR): 703-222-3700, 24 hours
  • Permit Specialists: 703-228-3800, 8am-4:30pm, Monday – Friday

Forty-eight (48) hours prior to the start of any excavation, notify Miss Utility at 1-800-257-7777

List of inspections required for residential builds and the time at which they occur.

INSPECTION TYPE PERMIT TYPE WHEN
1.) Footing Building Before pouring concrete
2.) Groundwork Plumbing Before backgrading
3.) Slab Building Before pouring concrete
4.) Foundation Walls Building Before pouring concrete walls, or for reinforce CMU walls.
5.) Backfill Building After waterproofing or before backfilling.
6.) Rough-in Plumbing, Mechanical, Electrical Before covering work & 1st Gas Test (if applicable)
7) Braced Wall Nailing Building Before building wrap or windows installed
8.) Framing Building After trade rough-ins (allows insulation)
9.) Insulation Building After insulating (allows close-in).
10.) Gas Test Plumbing Before concealing gas piping.
11.) Final Electrical, Mechanical, Electrical After work is complete
12.) Final Building After trade finals, before Certificate of Occupancy.
13.) Certificate of Occupancy Certificate of Occupancy After Finals
Other Inspections: (Timing depends on needs)
Service Electrical After upgrading service box
Temporary Power Electrical Before Virginia Power begins service
Concealment Ditch Electrical Before backfilling trench
Fireplace Building Fireplace hearth or throat inspections.
Sewer/Water Service Plumbing When tapping mains/before backfill
*SEQUENCE OF INSPECTIONS FOR RESIDENTIAL SINGLE-FAMILY AND TOWNHOUSE CONSTRUCTION *

 